Skip to content
Lumora

Battery storage

Keep the sunshine you make, and spend it when power costs most.

A battery stores what your solar array makes at noon and releases it in the evening, holds your demand below your contracted peak and keeps critical loads running through a grid fault.

148MWh
Battery storage installed
90%
Round-trip efficiency, measured at the meter
6,000cycles
Warranted cycle life, lithium iron phosphate
15years
Performance warranty on every cabinet
01How it works

Where storage fits on your site.

Every system we build connects to the same switchboard, so solar, storage and charging are designed together, against one grid connection.

01

Charge from surplus solar

When the array makes more than the site uses, the battery charges instead of exporting at a low price.

02

Shave the peaks

When demand nears your contracted capacity, the battery covers the top of the peak, so the grid never sees it.

03

Shift to the evening

Stored power runs cooling, lighting and chargers after sunset, when grid prices are highest.

04

Back up what matters

Critical circuits switch to the battery in milliseconds when the grid drops, and back again when it returns.

02Who it suits

The sites that gain most.

If your site is on this list, a site assessment will usually find a system that pays for itself.

  • Logistics and warehousing

    Evening and night shifts that can run on the afternoon's solar.

  • Manufacturing

    Short, sharp peaks from presses, kilns or compressors that set the capacity charge.

  • Retail

    Cold rooms and freezers that must keep running through a fault.

  • Agriculture

    Milking, cooling and ventilation at dawn and dusk, when the sun is low.

  • Education

    Sites near the limit of their grid connection that are adding chargers.

03Key figures and specs

What we build, in numbers.

The ranges we design within. Your proposal names the exact equipment and why it was chosen.

Capacity
100 kWh to 20 MWh
Power
50 kW to 10 MW
Chemistry
Lithium iron phosphate (LFP), no cobalt
Enclosure
Outdoor cabinets and containers, IP55, with gas detection and fire suppression
Control modes
Solar self-use, peak shaving, tariff shifting and backup, run together
Switchover to backup
Under 20 ms for critical circuits
Monitoring
State of charge, cell temperatures and every cycle, watched from Rotterdam
04The process

Five steps, one team.

01

Load analysis

Half-hourly meter data shows your peaks, your night use and the solar you export.

02

Sizing and controls

Capacity and power chosen for the savings, with the control strategy written down.

03

Safety and permits

Fire risk assessment, siting and the network operator's approval.

04

Installation

Foundations, cabinets and the connection, planned around your operations.

05

Optimisation

We tune the controls in the first months as the real load profile comes in.

05Related projects

No. Peak shaving and tariff shifting pay for themselves on many sites without solar. With solar the case is usually stronger, because the battery stores power you would otherwise export cheaply.

Site assessment

Find out how much of your peak a battery could take.

An engineer reviews your meter data and roof, visits the site and sends a written proposal with a design, a yield model and the financing options that fit. It costs nothing and commits you to nothing.